Prelude
Looking around for a t-check adapter I found a seller, but unfortunately it was marked out of stock. Just the price made my day, I’m unable to spend some 3 to 4e3 Euros for a device like that. Nevertheless its specs were given for free download. Some 12 pages filled with a nice picture and a bunch of numbers about the specified frequencies. Instead I got a very cheap (15 Euro, delivery included) 3-leg N-Connector. A 50 Ohm load is included in the Eleshop N(m) Calkit. That should fit for my needs.
In the previous post I ended up with a calibrated LibreVNA and saved the calibration on disk. Now its time to use the VNA to measure our t-check 3-leg N(f)-Connector and a 50 Ohms load.
As the measurement itself is not a secret, I saved the data as a touchstone file, which I’m going to be read into this notebook. I saved it: t-check-100k-3G.s2p
s-parameter mixing and shaking
According to the Rohde & Schwarz paper T-Check-Accuracy-for-VNA-RS-1ez43_0e.pdf the s-parameters need to be mixed up in the following manner:
At first we have three terms to be used in the final formula, a, b, c_
\[
a = | S_{11} \cdot S^*_{21} + S_{12} \cdot S^*_{22} |
\]
\[
b = | 1 - S_{11}^2 - S_{12}^2 |
\]
\[
c = | 1 - S_{21}^2 - S_{22}^2 |
\]
These are used in combination to calculate the T-Check value:
\[
t_{check} = \frac{a}{\sqrt{b\cdot c}}
\]
Ideally it would result in a value of \(1\), lets do it …